Can 2 Rigger 8s be linked together to form a Rigger 16?

07/09/2010

No, you can set the start address of one Rigger 8 to be 1 and the second to be 9. That way each one will look at different sets of hoists but you can't get them to both talk down the same cable at the same time. There can only be one master on the line at a time, be it Vector, K2 or a Rigger handset.

The DIP Switch setting (which adjust the start address) can be found here. You could cable the Elevations so they were in two loops of 8 (but on 16 different addresses), so if you wanted to run them from a computer you would plug each loop into one of the two outputs on a uTransform or if you wanted to run them from a Rigger you would plug each loop into one Rigger.

 